PM1000 Power Distribution Units
 |
PM1000 Power Distribution units (PDUs)
support strip level metering to provide datacentre professionals the tools
they need to monitor, reduce, and manage their growing power consumption
costs of IT equipment. Thresholds can be created to allow datacentre teams to know before problems occur and minimize downtime caused by overloaded circuits. |
The ability to integrate with the DSView3 management
software enables IT managers to have a consolidated interface to access and
manage their IT equipment and also the supporting power infrastructure. The
optional DSView
3 Power Manager further enhances this by allowing historical reporting to
track power consumption, capacity and cost across individual PDUs, racks, rows
of racks, or entire data centres.
 |
- Measure and monitor power consumption
at the strip level
- Create thresholds to generate
alerts/notifications
- Flexible installation- IP and Serial
interface options
- Can be managed directly or integrated
with other Avocent solutions using the DSView 3 software
- Optional DSView 3 Power Manager for
historical reporting
|
Features and Benefits
|
Feature
|
Benefit
|
| Strip level and circuit level
metering with threshold and alert capabilities |
Provides preemptive notification of
any impending overload issues before they occur, and simplifies the task
of installing new equipment |
| On board web interface |
Can be installed for direct access
right out of the box or it can be configured as part of a larger
integrated solution using the DSView 3 software. |
| IP and Serial interface options |
Options to install by connecting
directly to the network or save IP connections by using the serial
interface to connect directly to Avocent appliances already connected to
the network. |
| Daisy chaining |
Saves the number of IP addresses or
console / KVM ports that are required to manage all power distribution
needs. |
| Integration with DSView 3 |
Single interface for management of IT
equipment and PDU's simplifies mapping of outlets to servers and other
equipment to reduce and minimizes power cycling the wrong equipment. |
| Integration with DSView 3 Power
Manager |
Track historical trends to measure
and monitor IT power consumption, capacity, and cost to understand what
issues exist and to make more informed decisions in the future. |
| Electronic Overcurrent Protection |
Electronic Overcurrent protection is
an added layer of protection that gets activated in the event of minor
overloads. During such events, outlets get turned off first instead of
the primary overcurrent protection (OCP) getting tripped. |
| Supports external sensors for
environmental monitoring capability |
Provides preemptive notification of
any impending environmental issues. |
| 5kW - 22kW power capacity with a
mixture of C13 and C19 outlets |
Simplifies the deployment of
high-density racks that include a wide range of equipment types and
power requirements. |
Specifications
| Environmental |
- Operating Temperature 10-50 C
- Storage Temperature -40-65 C
- Relative Humidity 20 to 80 percent operating,
5 to 95 percent non-operating
|
| Dimensions |
- Form Factor 0U vertical
Weight - 14.8 lbs (vertical without power cord)
Physical Dimensions (W x D x H)
- Vertical- 2.2 x 66 x 3.15 in (5.6 x 167.6 x 8 cm)
|
| Network Connection |
- Number 1
- Type 10/100/1000 Ethernet
|
| Safety Markings and
Approvals |
- UL, FCC, cUL, CE, VCCI, C-Tick, CB
Safety certifications and EMC certifications for this product are
obtained under one or more of the following designations: CMN
(Certification Model Number), MPN (Manufacturer's Part Number) or
Sales Level Model designation. The designation that is refrenefced
in the EMC and/ or safety reports and certificates are printed on
the label applied to this product.
|

NOTE 1: When one bank is at a maximum 16A, the other two banks shall not
exceed 12A per bank.
NOTE 2: When one bank is at a maximum 16A, the other two banks shall not exceed
8A total.
NOTE 3: When one bank is at a maximum 16A, the other two banks shall not exceed
16A total.
NOTE 4: When one bank is at a maximum 32A, the other two banks shall not exceed
13A per bank.
NOTE 5: When one bank is at a maximum 32A, the other two banks shall not exceed
23A per bank.
NOTE 6: This is a single bank unit therefore unbalanced/balanced bank currents
are the same.
For more information about Outlet Bank Assignment please refer to the
installer/user guide.
Diagram
Photos
Horizontal 6 Outlets

Vertical 24 Outlet - End

Vertical 24 Outlet - Middle

Vertical 24 Outlet

|
Related Photos |
|
 |
 |
|
Environmental Sensor - Front |
Environmental Sensor - Back |
Ordering Details
|
PM1000 PDUs - STRIP LEVEL METERING
CAPABILITY |
|
Description |
Part Number |
Price (CAD) |
| PM1000 1U Horizontal 1-ph 24A 200-240V, L6-30, 10 C13 ports |
PM1009H-401 |
$908 |
| PM1000 1U Horizontal 1-ph 16A 100-240V, detached L6-20, 10 C13 ports |
PM1011H-001 |
$756 |
| PM1000 0U Vertical 1-ph 24A 200-240V, L6-30, 21 C13 & 3 C19 ports |
PM1001V-401 |
$1,150 |
| PM1000 0U Vertical 3-ph 24A 200-240V, L21-30, 21 C13 & 3 C19 ports |
PM1002V-401 |
$1,271 |
| PM1000 0U Vertical 3-ph 40A 200-240V, Hubbell CS8365C, 21 C13 & 3 C19 ports |
PM1003V-401 |
$1,603 |
| PM1000 0U Vertical 3-ph 48A 200-240V, IEC 309 60A, 21 C13 & 3 C19 ports |
PM1004V-401 |
$1,694 |
| PM1000 0U Vertical 3-ph 24A 200-240V, L15-30, 21 C13 & 3 C19 ports |
PM1008V-401 |
$1,240 |
| PM1000 0U Vertical 1-ph 24A 200-240V, L6-30, 20 C13 ports |
PM1012V-401 |
$1,029 |
| PM1000 0U Vertical 1-ph 16A 100-240V, detached L6-20, 20 C13 ports |
PM1014V-001 |
$938 |
|
ENVIRONMENTAL SENSORS |
|
For PM1000, PM2000, and PM3000 PDUs |
|
Description |
Part Number |
Price (CAD) |
| Temperature and humidity combination sensor |
PMHD-THS |
$303 |
| Temperature only sensor |
PMHD-TS |
$242 |
|
HARDWARE SERVICE OPTIONS |
|
Description |
Part Number |
Price(CAD) |
PLUS Program, Next Day Replacement Service,
1 Year |
SCNT-PLUS-PM |
$61 |
| PREMIUM Program, 24x7 Support and Next Day Replacement Service, 1 Year |
SCNT-PREM-PM |
$93 |
* Prices shown are suggested retail prices in Canadian dollars. Dealers may sell for less.
FAQs
|
Question
|
Answer
|
| What is the
main difference between the PM 1000, PM 2000 and the PM 3000 products? |
The PM 1000 PDUs measure at the strip
level and do not include remote switching capabilities.
The PM 2000 PDUs have metering capability at the
outlet level and do not include remote switching capabilities.
PM 3000 PDUs have both metering and switching
capability at the outlet level. |
| What is
Electronic overcurrent protection? |
This is a feature built in to Avocent
PM 1000, PM 2000, and PM 3000 units that locks the outlets that are
being unused on a phase / strip where currents have exceeded programmed
thresholds. |
| Are PM 1000
units IPv6 compliant? |
Yes, through WebUI, CLI and DSView3. |
| Can multiple
PM 3000 and PM 2000 units be daisy chained? |
Yes, up to a total of 5 units or 128
outlets, whichever comes first. They can be daisy chained with either
Cyclades PM units or with other PM 3000 or PM 2000 units. |
| What are the different ways to
remotely manage PM 1000 PDUs? |
The PM1000 units can be managed the
following ways:
- Stand alone using the Onboard web interface
- CLI through a serial connection
- Serially connected to ACS 6000 console serves
- Serially connected to current KVM over IP
switches
- Centrally managed using the DSView3
management software and optional DSView3 Power Manager for real-time
and historical reports
|
| Do PM 1000, PM 2000 and the
PM 3000 units have an accessory to hold the output power cords connected
to IEC outlets? |
Yes. PM 1000 units includes clips for
all outlets. |
|
_
|